Temperature Cycle Test of Field Assembly Connector FAC-SC/UPC-01

Temperature Cycle Test of Field Assembly Connector FAC-SC/UPC-01

Test Purpose: Testing plays an important role in product process. We pay great attention to our products quality. So we will have tests very often. Here is another High and Low Temperature Cycle Test we did for Field Assembly Connector. This test is to make sure our connectors can withstand varying temperature conditions that it might be exposed to in the field. Customers can have confidence that our connectors will perform well as expected.

Sample Information

Sample Name Field Assembly Connector
Sample Mode FAC-SC/UPC-01
Sample Condition Good Appearance
Sample Pic

Test Information

Test Project High and low temperature cycle test
Test Standard -10℃-+65℃
Test Date June 16th, 2021
Test Period 12hrs
Test Equipment Programmable Constant Temperature And Humidity Test Chamber

Test Process: Connect products and put in the equipment. Turn on the equipment and set temperature. The test exposes connectors to the high temperature and low temperature of -10℃-+65℃. Routine 12 hours 4 high and low temperature cycles. The rate of heating and cooling is 1 degree Celsius per minute.

Share this post